PDI Home Precision Diagnostic Instruments PDI top banner
PDI Home Products About PDI Contact PDI FAQ Privacy and Security Warranty

PDI Online Store

Tel: (303) 650-5638

Model 925 Automotive DMM Specifications:

DC Voltage (Autoranging)

Range

Resolution

Accuracy

Impedance

660mV

0.1 mV

±0.05%

>9.1MW

6.6V

66V

660V

750V

AC Voltage (Autoranging)

Range

Resolution

Accuracy 

Impedance

660mV

0.1mV

±2.0%

>9.1MW

6.6V

66V

660V

1000V

DC Current

Range

Resolution

Accuracy

660mA

0.1mV

±1.0% on 660µA to 66mA range

±1.5% on 400mA range

±3.0% on 20A range

6600mA

66mA

400mA

20mA

AC Current 

Range

Resolution

Accuracy

660mA

0.1mV

±1.5% on 660µA to 66mA range

±2.0% on 400mA range

±3.5% on 20A range

6600mA

66mA

400mA

20A

Resistance (Autoranging)

Range

Resolution

Accuracy

660W

0.1W

±1.0% on 660Ω, 6.6KΩ, 66KΩ, 660KΩ ranges

±2.0% on 6.6MΩ range

±3.5% on 66MΩ range

6.6kW

66kW

660kW

6.6MW

66MW

Frequency (Autoranging)

Range

Resolution

Accuracy

Sensitivity

66Hz

0.01Hz

±0.1%

3.5V ms

660Hz

6.6KkHz

66KHz

200kHz

Capacitance (Autoranging)

Range

Resolution

Accuracy

6.6nF

1.0pF

±3.0% on 6.6nF, 66nF, 660nF, 6.6µF, 66µF, 660µF ranges

±5.0% on 6.6mF range

66nF

660nF

6.6mF

66mF

660mF

6.6mF

Duty Cycle

Range

Resolution

Pulse Width

Accuracy

5.0% to 95.0%

0.1%

>100mSec

±2.0%

Temperature

Range

Resolution

Accuracy

-20°C to 1000°C

0.1°C

±2.0% from –20° to10°C

±1.0% from 10° to200°C

±3.0% from 200° to 1000°C

±2.0% from-4° to 50° F

±1.0% from 50° to 400°F

±3.0% from 400 to 1832°F

-4°F to 1832°F

0.1°F

Tachometer

Range

Resolution

Accuracy

600 to 6600 RPM

1 RPM

±2.0%

6600  to 12000 RPM

Dwell Angle

Range

Resolution

Accuracy

to 90°  (4 Cyl.)

0.1°

±2.0%

to 72°  (5 Cyl.)

to 60°  (6 Cyl.)

to 45°  (8 Cyl.)

Pulse Width

Range

Accuracy

0.1mS  to 10.0mS

±2.0%

 

Customer Service:

Monday - Friday:

7:00 AM - 5:00 PM MT

 

Email: sales@pdimeters.com

 

Precision Diagnostic
Instruments

7581 W. 103rd Avenue

Westminster, CO. 80021

 

Promotion

 

 

|Home | Products | About PDI | Contact Us | FAQ | Warranty | Privacy and Security | Site Map |

Copyright © 2008 Precision Diagnostics Instruments | website design and development: JR Web Design